Updated November 2026
A solar generator buyers guide spreadsheet v4 is a simple comparison sheet that lines up each power station’s capacity, output limits, charging options and your own load list in one place. In this guide you will build that sheet step by step, fill it with your household’s real numbers, and use the results to shortlist units that will actually keep your fridge, CPAP and sump pump running through an outage.
Why a Spreadsheet Beats Comparing Spec Sheets
Product pages list capacity in watt-hours, output in watts and charging speed in watts, but they rarely tell you how those numbers combine for your house. A spreadsheet forces the comparison into the same units and the same math for every model. It also keeps you honest: when a unit looks great on paper, the rows you filled in will show whether it covers your fridge overnight or only your phone charger. If you are new to backup sizing, the broader background in Using a Solar Generator During a Power Outage: A Practical Plan is a useful companion read.
Shopping for one? See our guide: 6 Best Used Solar Generators for Sale: Buyer's Guide for Home Backup.
Step 1: Build Your Load List
Start with the devices you truly need during an outage, not everything in the house. For each one, record its rated wattage (usually on a label or in the manual), its typical running wattage, and how many hours per day it runs. Motors and compressors have a higher startup surge than their running draw, so note that separately.
- List each essential device in column A.
- Enter rated watts in column B. Check the label, not a guess.
- Enter daily hours in column C. A refrigerator might run about 8 to 10 hours in a 24-hour period, depending on the unit and room temperature. Your appliance’s energy label or manual can help estimate this.
- Calculate daily watt-hours in column D with the formula =B*C.
- Note surge or startup watts in column E for motor loads.
Sample Load Rows
| Device | Running Watts | Hours per Day | Daily Watt-Hours | Surge Note |
|---|---|---|---|---|
| Refrigerator (typical full-size) | 100 to 150 | 8 to 10 | About 800 to 1,500 | Compressor startup spike |
| CPAP machine | 30 to 60 | 8 | About 240 to 480 | Low surge |
| Sump pump (1/3 HP, typical) | 700 to 1,000 running | Varies with rainfall | Plan for bursts | High startup surge |
| Wi-Fi router and modem | 10 to 20 | 24 | About 240 to 480 | None |
Treat these ranges as placeholders. Replace them with the figures printed on your own equipment, since a unit’s actual draw can differ considerably from typical values.
Step 2: Add Your Capacity and Output Columns
Create a second block of rows, one per generator or power station you are considering. Use the same column structure so you can compare them directly. The columns you need are:
- Usable capacity (Wh): Manufacturers often quote total capacity, but battery management systems reserve some energy. Check whether the spec is total or usable and enter the usable figure if given.
- Continuous output (W): The sustained load the inverter can supply.
- Peak or surge output (W): Important for sump pumps and refrigerators.
- Outlet types: Count AC, USB-A, USB-C and any 12V outputs.
- Charging inputs: Solar input in watts, AC wall charging time and any car charging option.
- Expandability: Whether extra battery modules are sold separately and the maximum capacity they allow.
For a clearer picture of what different output tiers support, see What Can a 1000W Solar Generator Run? (With Runtime Math) and What Can a 2000W Solar Generator Run? (With Runtime Math).
Step 3: Calculate Runtime for Each Load
Runtime is the core test of the spreadsheet. The basic formula is:
Runtime (hours) = Usable Capacity (Wh) × Inverter Efficiency ÷ Load (W)
Inverter efficiency is often in the range of about 80 to 90 percent, though exact figures vary by model. If you prefer a conservative estimate, use 85 percent as a middle value. Then compare runtime against the outage length you want to plan for.
Worked Example
Suppose a unit has 2,000 Wh of usable capacity and you want to run a 60 W CPAP for 8 hours overnight. Daily energy need is 60 × 8 = 480 Wh. Accounting for 85 percent efficiency, you need roughly 480 ÷ 0.85, or about 565 Wh from the battery. The unit would cover that load more than three times over, leaving room for a refrigerator. For CPAP-specific planning, read Using a Solar Generator or Power Station for a CPAP Machine.
Refrigerator Check
A refrigerator often needs the most energy. If your daily fridge figure is about 1,200 Wh, you will need a battery large enough to hold that energy plus your other loads. The sizing logic is covered in What Size Solar Generator to Run Refrigerator and Freezer? Sizing Guide.
Step 4: Add a Solar Recharge Column
Backup is only half the picture. A unit that takes three days to recharge may not suit a long outage. Add a column for expected daily solar harvest:
- Find your panel wattage and the peak sun hours for your location. Peak sun hours vary by region and season, so use a reliable local source or a national solar resource map.
- Estimate daily harvest as panel watts × peak sun hours × 0.75, where 0.75 is a rough allowance for system losses.
- Compare that harvest to your daily load in watt-hours. If harvest is below daily use, the battery will drain over multiple cloudy days.
If charging speed is a concern, Why Is My Solar Generator Charging Slowly? Causes and Fixes covers common limits such as panel voltage mismatch and input caps.
Step 5: Score and Shortlist
Add a final column with a simple pass or fail for each device, then a total. Mark a unit as a pass only if it meets all three tests: continuous output covers your running watts, surge output covers motor startup, and usable capacity covers your target outage length. Sort the remaining options by how much spare capacity they leave, since spare capacity protects you on bad weather days and during longer outages.
Checklist Before You Buy
- Load list complete, using label values
- Usable capacity confirmed, not just total
- Continuous and surge watts both checked against your worst-case device
- Runtime calculated for your target outage
- Solar harvest estimated with realistic peak sun hours
- Expansion options noted if you may need more storage later
- Warranty length and support terms reviewed in the manufacturer’s documentation
Common Mistakes
- Using total capacity as usable capacity. This inflates runtime. Always check which figure a spec refers to.
- Ignoring surge. A unit that runs a fridge may still trip when the compressor kicks on. Compare surge rating to the device’s startup draw.
- Forgetting standby loads. Routers, clocks and chargers add up over 24 hours.
- Assuming full sun every day. Plan for overcast periods, not ideal ones.
- Skipping the outage-length test. A unit that covers one night may not cover three.
- Trusting one set of numbers. Verify key specs against the manufacturer’s current documentation before purchase.
Recommended gear
A few supporting items make the spreadsheet process and the resulting setup easier to manage.
- Plug-in watt meter: Measures actual draw from appliances, which is more reliable than nameplate figures for filling in your load list. View on Amazon
- Heavy-duty extension cord rated for outdoor use: Useful for safely routing power from a unit placed outdoors to indoor devices, when ventilation and safety guidance allow. View on Amazon
- Solar panel with MC4 connectors: Matching connectors make it easier to add charging input once you know your solar harvest target. View on Amazon
FAQ
What should a solar generator buyers guide spreadsheet v4 include?
At minimum: your load list with running and surge watts, each unit’s usable capacity and output ratings, a runtime formula, a solar recharge estimate and a pass or fail column for each device.
Should I use total or usable capacity?
Use usable capacity whenever the manufacturer provides it. If only total capacity is listed, apply a conservative efficiency factor and treat your runtime as an estimate.
How do I find the surge wattage of my refrigerator?
Check the manufacturer’s manual or specification sheet. If it is not listed, a plug-in watt meter can show startup spikes, though brief peaks may be missed by some meters.
How many hours of runtime should I plan for?
Many households plan around the outage lengths common in their area and the medical needs of anyone who depends on powered equipment. For medical devices, consult your provider about backup planning.
Can a solar generator run a sump pump?
It can, provided the unit’s surge rating exceeds the pump’s startup draw and the battery holds enough energy for expected run cycles. Check the pump’s nameplate and the unit’s specifications together.
How often should I update the spreadsheet?
Update it when you add or remove devices, change your solar panel setup, or when new product specifications become available.
Is this spreadsheet a substitute for professional electrical advice?
No. For connecting a generator to home wiring or planning a whole-house system, consult a licensed electrician.
Conclusion
A well-built comparison sheet turns scattered spec sheets into a clear decision. Start with an accurate load list, run the runtime and surge checks for each candidate, then add solar recharge as a final filter. Done carefully, the spreadsheet will tell you which unit fits your home and which ones only look good on paper.

